4、产品型号及名称①聚氯乙烯绝缘耐火计算机控制电缆型号产品名称NH-DJVV铜芯聚氯乙烯绝缘及护套耐火计算机控制电缆NH-DJVVP铜芯聚氯乙烯绝缘及护套铜丝屏蔽耐火计算机控制电缆NH-DJVPV铜芯聚氯乙烯绝缘及护套铜丝分屏蔽耐火计算机控制电缆NH-DJVPVP铜芯聚氯乙烯绝缘及护套铜丝。

Low smoke and low halogen flame retardant control cables are suitable for the use of ac rated voltage 450/750v and below control, monitoring circuit and protection line with certain environmental protection re Operating conditions (1) rated voltage U0/U is 450/750v; (2) the cable conductor allowed to work at 70 ℃ for a long time; (3) the cable temperature under installation should not below 0 ℃, allowed bending radius; recommended by (4) the cable without armor layer shall be no less than 6 times the outer diameter of the cable; (5) the cable with armored or copper belt shielding structure shall be no less than 12 times the outer diameter of the cable; (6) the soft cable with shield layer structure shall be no less than 6 times of the cable. Technical re for 20 ℃ dc resistance conductors shall comply with the terms of GB9330.1 insulation resistance are shown in table 3 - table 6. The fire retardant performance test of the cable conforms to the provisions of GB/T18380. If the user does not require it to meet the re of class C fire retardant. The cable smoke concentration shall comply with the provisions of GB/T17651, and its light transmittance shall be 60%. The halogen content should not exceed 100 mg/g. Other performance re are the same as GB9330.
矿用通信电缆|MHYV矿用通信电缆|MHYA32矿用铠装通信电缆|MHYAV矿用通信电缆|MHYBV矿用通信电缆|矿用通讯电缆|矿用屏蔽通信电缆MHYVP|矿用屏蔽通信电缆MHYVRP|矿用通信电缆MHYV22矿用通信电缆执行标准:MT818.简要说明:命名代号:•煤矿用通信电缆……MH(HU)•铜。
Sheathed control cable products use feature: the cable conductor of long term working temperature should be allowed no more than 70 ℃. When the cable temperature under installation should not below 0 ℃, when laying bending radius should not less than 10 times of cable diameter. The cable with armor layer or copper band shielding structure shall not be less than 12 times the outer diameter of the cable.

When the data is transmitted at a high speed, the transmission line effect appears. At this point, the characteristic impedance of the load must match the output, otherwise, the echo will reflect and cannot work normally. Even though in some cases, can be done by resistance in the end of the parallel matching impedance matching, but in the long run, when the resistance change and come back down for some reason, besides, the disadvantages of this also leads to increased power consumption.
左侧X1并联的是接触器M1的常开点。
左右两条竖的线分别是对应火零线当我们按下X1按钮。
X1接通X2接的是常闭也是同的M1线圈就通电了接触器就要动作。
常开点就会闭合。
左边与X1并联的M1接触器常开点也闭合。
再当X1松开的时候由于M1闭合了这条电路还是通的,从M1到X2保持给M1接触器的线圈供电。
当按下X2。
M1线圈断电左边M1接触器的常开点也断开,整个接触器就断电了。
这个就是我们常说的起保停电路。
Armored communication cable mechanical protection layer: type 53 adopts 0.15mm thick corrugated steel belt, which is longitudinal wrapped on the basic cable and overlapped on both sides. The surface of the steel belt is coated with plastic to prevent corrosion and water intrusion.
主要技术指标1.电缆应经受环境温度下工频电压试验3kV,5min不击穿2.电缆的透光率应符合下表电缆外径D(mm)透光率(%)≥电缆外径D(mm)透光率(%)≥D>40705