孟津耐火电力电缆NH-内敛
。。。。。。其线对的绝缘色谱及序号分别是以白、红、黑、黄、紫(a线)五种颜色作为领示色,蓝、桔、绿、棕、灰(b线)五种颜色作为循环色循环而成。缆心结构是将25个全色谱线对先绞合成10或25对基本单位,再将若干个基本单位(或子单位)绞合成50对或100对的超单位,由若干个超单位总绞合成缆心,构成大对数电缆。
Our factory was founded in 1971, is a production and sales of various kinds of flame retardant communication cable, shielded cable for mine, mine screen communication cable, mine telephone cable, shielded cable for mine, mine fire retardant cable, flame retardant cable, mining flame-retardant control cable, communication cable, mining cable, flame retardant mining communication cable, communication cable, mine cable, mine, mine control cable, cable for mine monitoring, sensors, cable, cable, control cable, computer cable, flame retardant cable, shielded cable. City communication cable, railway cable, power line, electrical e wire and cable, video line, special cable. And other professional manufacturers. Enterprises with more than 300 employees, engineering and technical personnel more than 30 people, the factory goes to 20000 square meters, owns fixed assets of 15 million yuan, the total number of companies have production and inspection e more than 120 units (pieces), annual output value of 150 million yuan.
由于含卤阻燃电缆(包括阻燃电缆、低卤低烟阻燃电缆)在燃烧时会释放具有腐蚀性的卤酸气体,大大阻碍消防工作从而耽误救火时间并加剧火势蔓延,在人口密度较高的公众场所应尽量设计选用无卤低烟阻燃电缆。在人口密度较小的作业区可以选用任意一种阻燃电缆。阻燃电缆分为A、B、C3类,其中A类阻燃电缆性能较B、C类更优,价格也最贵。设计人员提供订货清册时应标明阻燃电缆的类别。从外观上无法区分阻燃电缆的A、B、C类别,只有靠制造厂家进行供货保证,在设计选用时应慎重选择电缆制造厂家。孟津耐火电力电缆NH-内敛
产品介绍-通信电源用阻燃软电缆通信电源用阻燃软电缆标准:YD/T产品型号:ZA-RVV(ZRRVVZRVVRRVVZ)通信电源用阻燃软电缆 ZA-RVV22(ZRRVV22ZRVVR22RVVZ22)通信电源用阻燃钢带铠装软电缆通信电源用阻燃软电缆是适用于通信局(站)及高层建筑等电源的。
ia-K2YV(EX)本安型PE绝缘、PVC护套二芯绞合屏蔽仪用电缆固定敷设在室内、电缆沟或管道中ia-K2YV(EX)R本安型PE绝缘PVC护套二芯绞合屏蔽仪用软电缆适用于要求柔软的场合ia-K3YV本安型PE绝缘PVC护套三芯绞合屏蔽控制电缆适用于要求柔软的场合ia-K3YVY本安。
BVR相比BV线来说要软、过流能力强、施工更方便,价格也要贵一些。由于BV线是单股线和同截面积BVR相比,它的铜丝要粗,当温度长期较高时不容易烧断;BVR线的铜丝比较细,温度较高时容易烧断其中一两根。只要电线中有一两根铜丝被烧断,那么烧断截面积减少,电阻更大,电线更容易被烧毁。在实际应用中,由于BVR线比较软,时间一长接头容易松动;而BV线相对来说就好很多,在家装中为了防止接头松动都要采取“挂锡”工艺。
无卤低烟阻燃电缆和含卤阻燃电缆相比,有低腐蚀、低烟的优点,但电性能及机械性能明显降低,在进行电缆敷设时,无卤低烟阻燃电缆应较含卤阻燃电缆有更大的弯曲半径。在进行电缆敷设设计时,不宜将非阻燃电缆和阻燃电缆并列敷设,不宜将不同阻燃类别的阻燃电缆并列敷设。
阻燃电缆标准:电缆涉及火灾安全的主要技术指标是CO2电缆的阻燃性、烟雾的密度和气体的有毒性。美国防火标准较关注前两个问题,欧洲和美国对火灾安全有着完全不同的观点。
美国传统的概念认为:火灾的根源在于一氧化碳(CO)毒气的产生以及其后的燃烧过程中CO转化为CO2的热释放,控制燃烧过程中的热释放量可减少火灾的危害。欧洲传统以来深信:在燃烧中产生的卤酸(HCL)释放量、气体腐蚀性、烟雾浓度及气体毒性是决定人们能否安全脱离火灾现场的主要因素。
(1)、低烟无卤电缆的阻燃等级根据GB/T规定的试验条件,低烟无卤电缆的阻燃等级分为A、B、C、D四个等级表1阻燃等级供火温度供火时间成束敷设电缆的非金属材料体积炭化高度自熄时间A≥815℃40min≥7升/米≤2.5米≤1hB≥815℃40min≥。
5.电缆允许弯曲半径:非铠装电缆最小为电缆外径的6倍铜带屏蔽或钢带铠装电缆最小为电缆外径的12倍氟塑料绝缘和护套电缆最小为电缆外径的8倍四:基本型号及名称(ZR192-)KFF氟46(进口PFA)绝缘和护套控制电缆(ZR192-)KFFP氟46(进口PFA)绝缘和护套铜丝编织屏蔽控制电缆(ZR1。
RVVZ cable, RVV cable, RVVP cable, ZRVVR cable, ZRYJVR cable VVP shielding cable implementation standard jbRVVP shielding cable product introduction: RVVP shielding cable, rated voltage 300V/300V. Some core from 2 to 24 core, according to the national standard color separation between more than two core twisted into line, direction of outer stranded for right-handed, soft rounded oxygen-free copper wire or tin plating oxygen-free copper wire shielding, widely used in instruments, meters, building intercom, monitoring, monitoring control installation. Implementation standard: jbproduct long-term mass supply packaging specification 200 m/roll; 500 meters/anaerobic copper coil wire core material number 1 ~ 24 core sheath material PVC/PE wire 26 largest diameter (mm) nominal section 0.12 ~ 2.5 (was) RVVP RVVP shielded cable core: twisted into cable, insulated conductor (PP) RVVP winding and polyester film screened cable sheath: black/white PVC shielded cable USES: used in building automation control system, anti-theft alarm system, fire control system, three table from copying systems, communications, audio, sound system, meter, electronic e and automation devices such as anti jamming circuit connection.
为了评定线缆的阻燃性能优劣,国际电工委员会分别制定了IEC60332-1、IEC60332-2和IEC60332-3三个标准。IEC60332-1和IEC60332-2分别用来评定单根线缆按倾斜和垂直布放时的阻燃能力(国内对应GB12666.3和GB12666.4标准)。IEC60332-3(国内对应GB)用来评定成束线缆垂直燃烧时的阻燃能力,成束线缆垂直燃烧时在阻燃能力的要求上要高得多。
IEC60332-1/BS4066-1阻燃等级(单根电线或电缆垂直燃烧测试FlameTestONSingleVerticalInsulatedWires/Cables)
交流接触器铁芯直流接触器线圈通入的是直流电,没有涡流和过零点的情况,铁芯由整块软钢制成的,一般为U型。线圈匝数不一样。交流接触器线圈匝数少,线径粗,电流大。直流接触器线圈细长,匝数特别多。可操作频率不同。交流接触器启动电流大,操作频率最高为600次/小时。直流接触器操作频率可高达2000次/小时。触点灭弧装置不同:交流接触器采用栅片灭弧装置,直流接触器则采用磁吹灭弧装置。根据以上不同,可以分析出:交流接触器线圈接入直流电时:没有了感抗,线圈变为纯电阻负载,线圈匝数少,电阻较小,电流会很大,使线圈发热烧坏。
b.周围环境温度:25℃ c.土壤热阻系数:1.0K•m/Wd.直埋深度:0.7m e.不同环境温度下载流量校正系数:环境温度(℃)校正系数940.88 ①电缆导体的长期允许工作温度:≤90℃ ②短路时(最长持续时间不超过。