新昌铠装矿用电缆WD-MYJY23淡雅
缆芯包带:用聚脂薄膜带纵包缆芯。屏蔽:铝泊屏蔽。护套:黑色(白色)低密度或中密度聚氯乙烯。室内通信电缆用途:本产品供交流额定电压500V或直流电压1000V及以下配电装置中电器,仪表接线之用。产品使用特性:电缆导体的长期允许工作温度应不超过70℃。
适用于矿用控制电缆适用于交流额定电压u0/u为450/750V及以下的控制监控回路及保护线路和配电装置中电器仪表的连接线。执行标准:MT818-2009.1/TX严格按照煤矿安全有关规定。
我们厂生产的矿用控制电缆型号规格范围使用场合MKVV,MKVVP,MKVVP2 0.5-10mm2,2-61芯,适用于弱电控制系统或强电磁场干扰区MKVV22,MKVV20 0.5-10mm2,4-61芯 MKVV32,MKVV30 0.5-10mm2,7-61芯 MKVVR 0.5-6mm2,2-61芯 MKVVRP 0.5-4mm2,2-61芯 MKVVP22,MKVVP2-22 1.5-10mm2,4-61芯 MKVVP2-22-1 1.5-10mm2,4-61芯,主要用于500KV变电站与发电厂配电装置及强电磁场干扰区。
Precautions for installation of power cables: keep 2m distance when the cable is installed in parallel with the thermal pipe, and 0.5m should be maintained when crossing. The cable shall be installed at a distance of 0.5m in parallel or across other pipelines. When the cable is directly buried and installed, the direct buried depth of 1-35kv cable is less than 0.7m. When 10KV and below cables are installed in parallel, the net distance between them shall not be less than 0.1m and 10-35kv shall not be less than 0.25m. The distance of cross installation is not less than 0.5m. Cable laying temperature lower than 0 ℃, bending radius: multi-core cable or 15 (D + D), a single cable 20 or more (D + D), (D for cable diameter, D) for the conductor diameter. ? 6KV and above cable connector:? When installing the terminal head of the cable, the semiconductor electrical shielding layer must be stripped off. During operation, the insulation shall not be damaged. The shield end should be flat and the graphite layer (carbon particles) should be clean. (2) plastic cable end copper tape screened and armor must be good grounding, the short circuit also follow this principle, avoid unbalanced three-phase run ShiGang armoured end produce inductive electromotive force, and even "lighter" and sheath and other accidents. It is required to use my tinplate to braid copper wire for grounding lead. When connecting with the cable copper belt, it should be welded with chromium-iron tin. ? The shield of three-phase copper tape should be connected with ground wire respectively. Note that the shielded ground wire and steel armor ground wire should be separately drawn out and insulated from each other. The position of the welded ground wire should be as low as possible. Basic re for cable terminals and intermediate joints: a. good conductor connection; B. The insulation is reliable, and it is recommended to use irradiated cross-linked heat-shrinkable silicone rubber insulation materials; C. good sealing; D. sufficient mechanical strength to meet various operating conditions. The end of the cable must be used to prevent water and other corrosive materials from corroding, in order to prevent the water tree caused by the aging of the insulation layer and breakdown. Crane or forklift should be used for the loading and unloading of cables. It is forbidden to run flat or lay flat. For installation of large cables, cable laying cart should be used to avoid external damage or abrasion caused by manual dragging. If the cable cannot be laid in time for some reason, it should be stored in a dry place to prevent sunlight from exploding and water entering the end of the cable. ? Note: the installation of wire and cable should be familiar with the performance of wire and cable installation personnel or full-time technical personnel, if there are still unclear matters, ball related technical department or technical department of our factory.
RS485接口连接器采用DB-9的9芯插头座,与智能终端RS485接口采用DB-9(孔),与键盘连接的键盘接口RS485采用DB-9(针).RS-485通讯电缆2X0.5 2X0.75 2X1.0 2X1.5RS-485通讯电缆在一般场合采用双绞线就可以,但在要求比较高的环境下可以采用带屏蔽层的双绞。
但要考虑到实时查看监控的带宽,每个连接占用4M,一条1000M的链路可以支持250个摄像头被调试调用。每台接入交换机接24个摄像头,250/24,相当于网络可以承受每个摄像头有10位用户在实时查看的压力。核心交换机核心交换机,需要考虑交换容量以及到汇聚的链路带宽,因为存储是放置在汇聚层的,核心交换机没有视频录像的压力,即只要考虑多少人看多少路视频即可。假设该案例内,有10人监看,每人看16路视频,即交换容量需要大于10*16*4=640M。
它的使用特性经国家检测为煤矿用控制电缆导体的长期允许工作温度为70℃,电缆敷设温度应不低于0℃。煤矿用控制电缆允许的弯曲半径:对有铠装或铜带屏蔽结构的电缆应不小于电缆外径的12倍。对有屏蔽层结构的软电缆,应不小于电缆外径的6倍。对无铠装层的电缆应不小于矿用电缆外径的6倍。铠装矿用电缆WD-MYJY23
MKVV电缆,MKVVP电缆,MKVVP2电缆,MKVV22电缆,MKVV32电缆,MKVVR电缆,MKVVRP电缆,MKVVP22电缆等规格型号的煤矿用阻燃控制电缆,推荐电缆芯数为2,3,4,5,7,8,,24,27,30,37,44,48,52,61芯
MKVV(2-14)*(4-6)mm2
,(2-10)*10mm2 (2-61)*(0.75-2.5)mm2 MKVV22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2
MKVVP(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2
MKVVP22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 。
HJYV/SA成束阻燃型聚乙烯绝缘、聚氯乙烯护套、呼叫通信电缆。HJYVP/SA成束阻燃型聚乙烯绝缘、聚氯乙烯护套、编织总屏蔽呼叫通信电缆。HJYVP2/SA成束阻燃型聚乙烯绝缘、聚氯乙烯护套、铜塑复合带绕包总屏蔽呼叫通信电缆。
目前,随着科技水平的不断提高,阻燃问题已由过去的卤素阻燃化,发展到低卤、无卤的阻燃化。ZA-VV/ZB-VV/ZC-VVZA-VLV/ZB-VLV/ZC-VLV聚氯乙烯绝缘聚氯乙烯护套A(B、C)类阻燃电力电缆可敷设在对阻燃有要求的室内、隧道及管道中。
下图表示单极方式与双极方式的简图,即在1个主极上的绕线方式。单极方式时,两个绕组绕制,如上图所示,一个线圈的终端是另一个线圈始端,它们共用一点。单极式时,C端接电源正极、A端接电源负极,或C端接正、A端接负的两种激磁状态下,定子主极及其前端的齿会产生的极性。单极方式必须要注意,A端子与“杠A”端子如通电,主极的合成磁通互相抵消,只产生线圈的铜耗。下图表示单极和双极的两相驱动电路及其电压波形,两相式通常用两相激磁方式(通常两个相加激磁电压)。
5、生产范围型号额定电压(V)导体标称截面(mm2)0.50.75芯数KVVKVVP450/-10KVVP2-4-KVV22-7-6KVV32。
矿用控制电缆:1、额定电压450/750v 2、电缆导体的长度允许工作温度为70摄氏度 3、电缆的敷设温度应不低于0摄氏度,推荐的允许弯曲半径; 4、无铠装层的电缆,应不小于电缆外径的6倍 5、有铠装或铜带屏蔽结构的电缆,应不小于电缆外径的12倍,6、有屏蔽结构的软电缆,应不小于电缆外径的6倍,
MT386-1995《煤矿用阻燃电缆阻燃性的试验方法和判定规则》及Q/TX 《煤矿用塑料绝缘控制电缆》 。
ZR-YJV22ZR-YJLV22ZR-YJV23ZR-YJLV23交联聚乙烯绝缘阻燃聚氯乙烯/聚乙烯护套钢带铠装动力电缆敷设在室内、隧道内直埋土壤,电缆能承受机械外力作用。2、可根据用户要求,生产0.6/1KV圆形导体结构或扇形导体结构的各类五芯电缆。