Precautions for installation of power cables: keep 2m distance when the cable is installed in parallel with the thermal pipe, and 0.5m should be maintained when crossing. The cable shall be installed at a distance of 0.5m in parallel or across other pipelines. When the cable is directly buried and installed, the buried depth of 1-35kv cable is not less than 0.7m. When 10KV and below cables are installed in parallel, the net distance between them shall not be less than 0.1m and 10-35kv shall not be less than 0.25m. The distance of cross installation is not less than 0.5m. Cable laying temperature is not lower than 0 ℃, bending radius: multi-core cable or 15 (D + D), a single cable 20 or more (D + D), (D for cable diameter, D) for the conductor diameter. 6 kv and above cable joint: (1) installing a cable terminal head, must be stripped semiconductor electric shielding layer, operation shall not damage the insulation, should avoid mark uneven situation, when necessary use sand paper to grind; The shield end should be flat and the graphite layer (carbon particles) should be cleaned. (2) plastic cable end copper tape screened and armor must be good grounding, the short circuit also follow this principle, avoid unbalanced three-phase run ShiGang armoured end produce inductive electromotive force, and even "lighter" and accidents such as burning sheath. It is required to use my tinplate to braid copper wire for grounding lead. When connecting with the cable copper belt, it should be welded with chromium-iron tin. The shield of three-phase copper tape should be connected with ground wire respectively. Note that the shielded ground wire and steel armor ground wire should be separately drawn out and insulated from each other. The position of the welded ground wire should be as low as possible. Basic re for cable terminals and intermediate joints: a. good conductor connection; B. The insulation is reliable, and it is recommended to use irradiated cross-linked heat-shrinkable silicone rubber insulation materials; C. good sealing; D. sufficient mechanical strength to meet various operating conditions. The end of the cable must be used to prevent erosion of water and other corrosive materials, so as to prevent breakdown due to the aging of the insulation layer caused by water trees. Crane or forklift should be used for the loading and unloading of cables. It is forbidden to run flat or lay flat. For installation of large cables, cable laying cart should be used to avoid external damage or abrasion caused by manual dragging. If the cable cannot be laid in time for some reason, it should be stored in a dry place to prevent sunlight from exploding and water entering the end of the cable. Note: the installation of wire and cable should be done by the installation personnel or full-time technical personnel familiar with the performance of wire and cable. If there are still unclear matters, please consult the relevant technical department or the technical department of our factory.
特种电缆就是有特殊用途、可以在特定场合使用的电缆,比如可以耐高温,耐酸碱,防白蚁,以及在轮船飞机核电站等场合使用的电线电缆。
就分类来说,它与电力、控制、计算机电缆等类别不属于同一种分类方法,也就是上列电缆中也包含有特种电缆在内。
一般特种电缆都需要制定企业内控标准。
特种电缆是一系列具有独特性能和特殊结构的产品,相对于量大面广的普通电线电缆而言,具有较高技术含量、较严格使用条件、批量较小、较高附加值的特点。
往往采用新材料、新结构、新工艺和新的设计计算。
产品标准:YD/T产品型号:ZA-RVV(ZRRVVZRVVRRVVZ)通信电源用阻燃软电缆ZA-RVV22(ZRRVV22ZRVVR22RVVZ22)通信电源用阻燃钢带铠装软电缆本产品适用于架空、管道、室内电缆沟、地下直埋。
使用时,建议铠装层两端接地,最内层屏蔽一端接地。
性阻抗为100Ω的双绞屏蔽电缆STP-100Ω(forFF&PROFIBUS-PA)onepair18AWG则应用于FF、PROFIBUS-PA总线,常用18AWG导体。
耐火电缆型号含艺1.型号组成阻燃和耐火电线电缆的型号由产品燃烧特性代号和相关电线电缆型号两部分组成,见图耐火电缆型号2、燃烧特性代号表代号名称Za阻燃ZA阻燃A类ZB阻燃B类ZC阻燃C类ZDb阻燃D类省略有卤W无卤D低烟U低毒N耐火NJ耐火加冲击NS耐火加喷水aZ为单根阻。
Proteus是电路仿真软件,就是搭建一个电子电路模拟实际的硬件电路,这样就不需要真正的硬件,我们就可以在仿真电路中关联Keil编译好的程序,来验证我们的代码。
这样的好处是只要有电脑我们就可以编程并验证,仿真电路是理想化的硬件,真正的硬件和仿真之间还是有很大区别的,尤其是高频电路和模拟信号,仿真电路刚开始可以用一下,还是要买一块单片机开发板作为实际硬件来学习。
单片机的学习我理解是是入门简单,深入有难度。
HYAC自承式电缆:适用于本地电信网的城市与乡镇电信线路,也适用于接入公用网的专用网线路。
吊线和电缆用同一外护层,经济实用,安装敷设方便。
HYA23铠装通信电缆机械保护层可以加在任何电缆上,以增加电缆的机械强度,提高防侵蚀能力,是为易受机械破坏和及易受侵蚀而设计的通信电缆。
航空航天、机车车辆、能源、钢铁、有色金属冶炼、石油开采、电机、建设等领域需用耐高温电线电缆。
长期连续工作温度125度、135度、150度、180度、200度、250度及250度以上的耐高温电线电缆,常用的有辐照交联聚烯烃、硅橡胶、氟树脂、聚酰亚胺、云母、氧化镁等电线电缆。
现介绍;两种新型耐高温电线电缆。
MHYVRPBV2X2.5+5X0.75矿用电缆
有强电与弱电之分,这里介绍一种强电用低感电缆。
此电缆带有热耗散装置,用于各类接触焊机、电弧焊机与气动焊钳间相连接的新型水冷式低感电缆,具有结构简单合理、冷却水流通量大、不会形成堵塞阻断和限流现象、散热效果好、使用寿命长等特点。
型号、额定电压、名称及用途:型号额定电压(V)名称用途KVV450/750铜芯聚乙烯绝缘聚氯乙烯护套控制电缆敷设在室内、电缆沟、管道固定场合KVVP40/750铜芯聚氯乙烯绝缘聚氯乙烯护套编织屏蔽控制电缆敷设在室内、电缆沟、管道等要求屏蔽的固定场合KVVP2450/750铜芯聚。
绝缘材料:高密度聚乙烯。
绝缘单线:在导线上连续挤制绝缘材料,采用规定的10种标准色谱以便识别,并保证电缆的电气性能。
绝缘线对:将绝缘单线按规定的色谱、不同的节距均匀地绞合成线对。
缆芯结构:绝缘单线绞合成对后采用同芯式或单位式绞合成缆芯,各单位采用不同的扎纱,以便施工、维护识别。
一广场喷泉池中有C三组喷头。
该广场喷泉设计要求如下:喷泉的喷水规律是:当按下启动按钮,A喷头先喷5秒,再是C喷头喷8秒,B仍然喷4秒,接着C组喷头喷5秒,再接着C三组喷8秒,最后C三组停止1秒,之后循环之前的过程,直到按下停止按钮整个系统才会停止喷水。
该设计所用设备是三菱FX3U系列plc,该喷泉示意图如下:该喷泉的时序图如下:PLC的I/O分配表:编程方法一:利用比较指令直接输入大于小于等于符号编写实现设计要求。
这种新型低感电缆也包括电缆和电缆端头上固装着的接头,且电缆也是由正极缆芯和负极缆芯同装于外胶管中构成。
由于这类低感电缆一般都是用于电压为25-50V、电流在7000-12000A之间的场合,冷却水在电缆中的短路导电现象基本上可忽略不计,在此低感电缆中没有使用隔离正极缆芯和负极缆芯的橡胶软管,只是特别设置了一条横断面呈轮辐状(俗称“梅花芯”状)的芯架,其“轮心”和相邻“辐条”间所围成的空间在顺轴线方向上即形成纵向沟槽,芯架上的纵向沟槽与电缆所配置的正极缆芯的总根数相同,其电缆部分就是以正极缆芯和负极缆芯分别搁于芯架的纵向沟槽内装置在外胶管中构成。
正极缆芯和负极缆芯的两端头部分别同极集合成束夹固于缆芯夹中,固装在接头上,电缆的外胶管的端头部套装在接头的尾端部,并用套装在外胶管外的收紧箍紧密封。
你需要理解接触器和继电器是什么东西,实际应用上他们是如何布线走线的,自锁回路是什么东西,互锁回路是如何实现几个继电器时间的关联控制的。
还有时间继电器,热保护这些基本的功能,毕竟这些东西用来隔离控制很多工控设备,你只有吃透它们的性能和应用逻辑,你才明白工业电气自动化是什么一种东西。
刚学继电器电路时候,可以自己安装一个电机正反转电路,星三角启动电路,加热和冷却温控电路等,这些实物能让你深入理解电气控制上“回路”的根本概念,而这个对于单片机和**语言的编程的程序员是不需要的,作为plc编程人员是必须掌握的。
6)电缆绝缘:PVC护套。
7)电缆外经:£18mm。
HYAT553铜芯实心聚烯烃绝缘填充式挡潮层聚乙烯护套双层纵包轧纹钢带铠装聚乙烯套市内通信电缆。
ZRCHYA铜芯实心阻燃聚烯烃绝缘挡潮层聚乙烯护套单层纵包轧纹钢带铠装聚乙烯套市通信电缆传输音频、150Hz及以下的模拟信号,可野外直埋敷设。