本公司生产的耐火型动力电缆为额定电压0.6/1KV铜芯电缆,还可以生产低烟无卤耐火动力电缆、高阻燃隔氧层耐火动力电缆,其耐火性能符合GB/T12666.6《电线电缆耐火特性试验方法》。
耐火系列动力电缆的整体性能优良可靠。
RVSP屏蔽双绞线;RVSP屏蔽双绞电缆RVSP(屏蔽双绞线,屏蔽电缆,屏蔽双绞电缆屏蔽双绞铠装电缆,并可提供屏蔽双绞铠装电缆技术咨询和屏蔽双绞铠装电缆的结构尺寸屏蔽双绞铠装电缆-屏蔽双绞铠装电缆大全-专业生产屏蔽双绞铠装电缆大型企业屏蔽双绞铠装电缆-屏蔽双绞铠装电缆大全-专业生产屏蔽双绞铠装电缆.。
Fire retardant control cable model zr-kvvp22, zr-kvvvp2-22, zr-kvvvvp2, our company has been supplying for many years: 2. Zr-kvvp, zrc-kvvp, za-kvvp, zrb-kvvp, za-kvvrp, zc-kvvvrp, zrc-kvrp, zrc-kvrp, zrb-kvvvvvvvvp2, krkvp2-vrkp22 -KVVP32, etc. Control cables for mine flame retardant control cables: MKVV mkvvvvvvvvvvvvvvvvvv32 MKVVVRP: this product can be manufactured according to gb9330-88 electricity union IEC227(1979) and jcs258c-1986; The product is suitable for low voltage power supply, protection and measuring line of ac rated voltage 450/750v and 600/1000v and below. Especially suitable for power plants and substation control lines of 500KV or below. Use plastic insulation special shielding control cable can be external electricity, magnetic field.
ZR-HYA23:铜芯实心聚烯烃绝缘挡潮层聚乙烯护套钢带铠装阻燃聚乙烯护套市内通信电缆。
ZR-HYAT22:铜芯实心聚烯烃绝缘填充式挡潮层聚乙烯护套钢带铠装阻燃聚氯乙烯护套市内通信电缆。
ZR-HYAT23:铜芯实心聚烯烃绝缘填充式挡潮层聚乙烯护套钢带铠装阻燃聚乙烯护套市内通信电缆。

Our new preferential treatment, cable packaging, cable with wooden shaft, freight all free,
可在小雨或小雪天检查线路是否发热。
7高温季节或高峰负荷时,重点检查设备发热情况。
8负责供电系统操作、巡查、维修、养护的人员必须持证上岗,必须熟悉电气设备情况和有关安全措施。
9配送电建立24小时运行值班制度,加强巡查,做好巡查记录;发现问题及时处理,并在值班记录及巡查记录中注明;不能解决的问题及时上报领导。
10配电设备由专职人员负责管理和值班,配电设备的停送电由值班电工操作。
11配电房室内的消防设施须定期检查,保持完好、有效,并有手持式气体灭火器。
AVVR型300/300V铜芯聚氯乙烯绝缘聚氯乙烯护套安装用软电缆。
KVVP2聚氯乙烯绝缘,聚氯乙烯护套铜带绕包屏蔽控制电缆同上。
KVV22聚氯乙烯绝缘,聚氯乙烯护套内钢带铠装控制电线敷设在室内、电缆沟中、管道内及地下,能承受较大的机械外力使用。
带钢丝绳PVC弹性体行车控制电缆,具有柔软、耐磨、防油等特性,线旁附钢丝绳,增强抗拉力。
适用于交流额定电压0.6/1KV及以下的行车、台车、传输机械等移动电器用动力传输线及控制、照明、通讯线路,本产品已广泛应用于冶金、电力、船舶、港口等行业。
The technical standard of railway signal cable product is as follows: horizontal TB/ t2476-1993 railway signal cable
Sheathed control cable products use feature: the cable conductor of long term working temperature should be allowed no more than 70 ℃. When the cable temperature under installation should not below 0 ℃, when laying bending radius should not less than 10 times of cable diameter. The cable with armor layer or copper band shielding structure shall not be less than 12 times the outer diameter of the cable.

Specializing in the production for the telecommunications, computing facilities, instruments and meters connect with wire and cable series product -- -- -- -- -- - RVVP coal RVV series of products: coal mine product logo - logo - Ann Ann symbol certification - coal Ann query - AnBiao query on a coal production license MA for certification to provide coal mine product logo AnBiao certificate, MA certificate, Ann card flame retardant communication cable MHYV MHJYV MHYBV MHYA32 MHYYV MHYY32 flame retardant cable: MHYVR MHYBV MHYV32 MHYVR MHYVP MHYBV MHYVR32 coal mine fire retardant control cable: HYA22 zrc-hya zrc-hyat zrc-hyat23 HYA23 HYA53 HYAT HYAT23 HYAT53 HYAC HJVV HPVV HPVV22 PYV azv HYV22 PYV22 control cable: KVV KVVP kvvv22 kvp2 kvp2 kvp2-22 KVVR KVRP special cable HP KP H Your satisfaction - our unremitting pursuit!
KVV22铜芯聚氯乙烯绝缘聚氯乙烯护套钢带铠装kvv22电缆450/7504-370.75-10敷设在室内,电缆沟、管道直埋等能承受较大机械外力的固定场合。
KVVP阻燃铜芯聚氯乙烯绝缘聚氯乙烯护套kvvp电缆450/7504-370.75-10敷设在室内,电缆沟、管道等要求屏蔽的固定场合。
2017年6月,某水电站电气作业人员将主变低压侧2号厂变分支电缆用细导线绑扎固定在B相电流互感器一次侧铜排上,绑扎导线磨损绝缘破损,致使B相铜排经绑扎导线接地,导致发电机定子一点接地保护动作停机。
类似电气作业者的“污点”、“野蛮施工”举不胜举,结果是砸了自己的招牌,丢了自己的名声。
人无信则不立,电气作业坏习惯须及时纠正。
出事必定违章,违章不能侥幸。
谁都不愿意去送死,安全靠的是意识、监护、安措和班组的关爱。
敷设时电缆的温度应不低于0℃,敷设时弯曲半径应不小于电缆外径的10倍。
有铠装层或铜带屏蔽结构的电缆,应不小于电缆外径的12倍。
ZR-KVVRP阻燃聚氯乙烯绝缘,阻燃聚氯乙烯护套铜丝编织屏蔽软控制电缆同上具有防干扰能力。

注:ZR-阻燃G-隔氧层NH-耐火三、生产范围型号芯数标称截面(mm2)型号芯数标称截面(mm2)额定电压(KV)额定电压(KV)0.6/10.6/16/6(6/10)8.7/10(8.7/15)26/35(26/45)CUALCUALCUA。