6:产品性能和参数:导体结构:由7/1.04mm软铜线绞合而成绝缘:绝缘采用交联聚乙烯,绝缘厚度1.0mm,绝缘电阻可以保证在10000MΩ/km以上。
护套:绝缘采用低密度聚乙烯黑色护套,护套厚度1.8mm,从而保证了电缆优良的绝缘性能,防水性能和防老化性能。
铁路信号电缆使用特性:(1)电缆的使用环境温度为-40℃~+60℃(2)电缆导体长期工作温度应不超过+70℃。
(3)电缆敷设环境温度:聚氯乙烯外护套电缆应不低于0℃;聚乙烯外护套电缆应不低于-20℃。
(4)电缆的允许弯曲半径:非铠装电缆应不小于电缆外径的10倍;铠装电缆应不小于电缆外径的15倍。
型号及名称2271EC52(RVV)铜芯聚氯乙烯绝缘聚氯乙烯护套(圆型连接软电线)2271EC52(RVV)主要技术参数标称截面芯×(mm2)线芯结构芯×根/直径电线参考数据外径(mm)重量(kg/km)20℃时导体电阻(Ω/km)不大于下限上限2×0.52×16/0.2。
Oil filled telecommunication cable identification and marking: cable outer surface sexual identification mark, mark at no more than alternate 1 m intervals, tag contents are: the diameter of wire, line number, cable type, factory name and year of manufacture, marking at no more than alternate 1 m intervals to mark on the surface, but with the tag stagger.

HYAT,HYAT53实心绝缘填充型通信电缆根据用户需要,可提供有加强机械保护层的铠装电缆HYAT53,HYAT53及高频隔离充油通信电缆,HYAT充油通信电缆,50对HYAT53通信电缆,100对通信电缆,500对通信电缆,1000对通信电缆,2000对通信电缆,2600对市内通信电缆。
下图五是分立元件组成的反相器振荡电路,这个电路可以通过瞬时极性法进行分析,两个三极管放大电路相耦合,经过倒相两次输入和输出就是同相关系。
可以将R4换成扬声器或led,在输出端可以输出振荡信号。
这个电路中各元件VTVT2为9013管,RR2=27K-100K,RR4=2K-5.1K,Ec=3v-6v,CC2=0.1-10uF;保证各个三极管工作中放大状态,电路必能起振。
图五分立元件反相器组成的振荡电路CD4069振荡电路有两种基本形式,还有一种改进电路;1.振荡电路形式之一,如下图六,该电路的特点是电源的波动将使频率不稳定,适合于小于100kHz的低频振荡情况。
2交接箱内接线端子的排列,以25对为一基本单位,与市话电缆的基本单位一致,并在端子标有编号,便于施工检修。
3接线模块的结构、排列及安装尺寸与3M公司产品完全一致,可以互相通用。
4箱体经静电喷塑处理,美观大方,线条清晰、防腐防水性能好使用寿命长。
2.最低环境温度:固定敷设-40℃非固定敷设-15℃。
3.额定电压U0/U450/7504.最小弯曲半径:无铠装层电缆应不小于电缆外径的6倍,带铠装层电缆应不小于电缆外径的12倍。
绝缘性能要求绝缘线芯应能经受GB/T3048.9规定的交流50Hz火花试验作为中间检查。
我国国家标准GB12666.6(等同IEC331)将耐火试验分A、B两种级别,A级火焰温度950~1000℃,持续供火时间90min,B级火焰温度750~800℃,持续供火时间90min,整个试验期间,试样应承受产品规定的额定电压值。
Cable conductor long term allowed working temperature to: fluorine plastic outer sheath is 200 ℃, PVC outer sheath is 105 ℃, silicon rubber outer sheath is 180 ℃.

Power cable, power cable | crosslinking cable, cross-linked cable | | control cable, control cable railway signal cable -- -- -- -- -- - railway signal cable | | soft cable, soft cable | | antiflaming fire-resistant cable, flame retardant fire-resistant cable | plastic copper lines, plastic copper wire | lines to weave, weave | computer cable, computer cable: : - telephone line, telephone line | multi-fiber sheath, multi-fiber sheath | shielding line, shielding wire | video line - video line | anti aging, anti aging cable | flame retardant control cable - flame retardant control cable, power - the power cord: : Airport light cable - airport lighting use | mining flame-retardant cable communications cables, mining flame-retardant communication cable | system special cable HAVP - system special cable HAVP | communication cable in the city - the city communication cable | | video monitor cable - video monitor cable | | high temperature resistant cable KFF - high temperature resistant cable KFF | with flame retardant cable soft structure of the telecom room (communication e power cord) RVVZ RVVZ22 ZA - RVV ZRVVR (6-240 was) expressway emergency telephone cable GHYAT GHYAT53 Railway signal cable PZYA (PTYA) PZYA23 PTYA23 DJYJVP, DJYPV, DJYJPV, DJVPVP, DJYPVP, DJYJPVP, JVV, JVVP DJYPRV airport lighting use cable DJ - JDKR - 500 - v 1 x2. 5 1 x4
二、电缆的型号、名称和用途序号型号名称使用范围1ZR-VVZR-VLVZR-VYZR-VLY阻燃聚氯乙烯绝缘阻燃聚氯乙烯/聚乙烯护套动力电缆敷设在室内、隧道及管道中,电缆不能承受机械外力作用ZR-VV22ZR-VLV22ZR-VV23ZR-VLV23阻燃聚氯乙烯绝缘阻燃聚氯乙烯/聚乙。
从而在1s内发生溢出的次数(即溢出率)可由公式所示:从而波特率的计算公式由公式所示:在实际应用时,通常是先确定波特率,后根据波特率求T1定时初值,式又可写为:电路详解3串行通信实验电路图下面就对所示电路进行详细说明。
最小系统部分(时钟电路、复位电路等)第一讲已经讲过,在此不再叙述。
我们重点来了解下与计算机通信的RS-232接口电路。
可以看到,在电路图中,有TXD和RXD两个接收和发送指示状态灯,用了一个叫MAX3232的芯片,那它是用来实现什么的呢?我们要知道计算机上的串口是具有RS-232标准的串行接口,而RS-232的标准中定义了其电气特性:高电平“1”信号电压的范围为-15V~-3V,低电平“0”信号电压的范围为+3V~+15V。
In order to evaluate the flame-retardant performance of wire cables, iec 60332-1, iec 60332-2 and iec 60332-3 were formulated respectively. Iec60332-1 and iec60332-2 are respectively used to evaluate the flame retardant capability of a single cable when it is laid on an incline and vertically (corresponding to GB12666.3 and GB12666.4 in China). Iec60332-3 (domestic e to gb) is used to evaluate the flame retardant capability of beam cable when it is vertical, compared with that of beam cable when it is vertical.

4、电缆安装敷设温度应不低于-20℃。
2、电缆导体长期允许工作温度为:氟塑料外护层为200℃,聚氯乙烯外护层为105℃,硅橡皮外护层为180℃。
3、电缆的敷设温度应不低于:聚氯乙烯护套电缆0℃,硅橡皮护套电缆-20℃,氟塑料护套电缆-20℃。