导体:多股铜导体,符合GB/T3956第5类(等同于IEC60228.5)。
绝缘:聚氯乙烯混合料(PVC)。
护套:柔性聚氯乙烯混合料(PVC),灰色(RAL7001)。
芯线标识:≤5芯,彩色芯线;黑色芯线白色数字编号,黄绿地线。

电缆结构:规格型号导体直径绝缘外径编织密度电缆外径SYV1/0.33裸铜1.9mm单层≥80%3.4±0.2mmSYV1/0.33裸铜1.9mm双层≥80%3.9±0.2mmSYV1/0.5裸铜3.0mm单层≥92%5.0±0.2mmSYV7/0.17裸铜3.0m。
Ratedpower-fre/U:0.6/1kV.•电缆导体的最高允许长期工作温度(PVC/XLPE):70℃/90℃.产品型号Table3Typeofproduct型号Type产品名称Nameofproduct适用范围及环境Applicabilityandurro。
Armoured oil filled telecommunication cable USES: armoured communication cable mechanical protective layer can be appended to the structure of the cable, with the mechanical strength of the cable, antierosion capability, is vulnerable to mechanical and vulnerable to erosion area and design of telephone cable. Any kind of laying can be adopted, which is more suitable for direct buried laying in rock area.

氟塑料计算机电缆,氟塑料仪表电缆规格范围型号标称截面(mm2)成缆元件结构全部型号0.5~2.5对线三线组四线组1~241~121~7氟塑料仪表电缆主要技术参数序号项目单位指标试验方法1电缆结构及导体电阻符合GB/T标准(IEC60228:2004)GB/T3048。
安装减震器可以降低噪音步进电机安装在机器上时,在固定电机处可垫硬质橡胶等减震器材,以便阻止与底板产生的共振。
此种方法降低噪音效果明显,被广泛使用。
具体方法有两种:一种为用厚度为几mm的硬质橡胶将安装步进电机的前面钢板夹成三明治状态,作为步进电机的前面连接板使用;另一种是将两片钢板用硬质橡胶像三明治那样连接,置于步进电机与安装设备之间。
这些称为装置减震器,其降低噪声效果明显,但步进电机要依靠安装底板散热,而橡胶材料的热传导性能差,要注意电机温升。
ZR-KVVP2铜芯绝缘和护套铜带屏蔽(阻燃)控制电缆。
ZR-KVVRP2-22铜芯绝缘和护套铜带屏蔽钢带铠装(阻燃)控制电缆。
电缆使用环境温度-40℃~+50℃,电缆敷设温度≥-10℃,在25℃时的温度≤95%,电缆敷设时弯曲半径:MHYV31、MHYVR型电缆≥10倍电缆外径其余型号电缆≥15倍电缆外径。
产品名称型号规格及范围:塑料绝缘和聚氯乙烯护套铁路信号电缆信号电缆PTYA23PTYAH,;PTYA;PZYA;PTYV;PTYY,;PTY22;PTY23;(PZY02;PZY03;PZY23PZY22)1/0.8mm(1/1.0mm)2-48芯适用于额定电压交流500V或直流1000V及以下的铁。
低烟无卤阻燃绝缘和护套电缆属于环保型电缆,适用于高层建筑、铁路等行业具有消防等特殊要求的场合。
二:产品执行标准GB、GB等效采用IEC502标准阻燃特性试验执行GB标准。
塑铜线类型BV线又分为:ZR-BV和-BV:铜芯聚氯乙烯绝缘阻燃电线:绝缘料加有阻燃剂,离开明火不自燃。
NH-BV:铜芯聚氯乙烯绝缘耐火电线:正常着火情况下还可以正常使用。
BV线学名:铜芯聚氯乙烯绝缘电线四、耐高温控制电缆氟塑料绝缘耐高温控制电缆用途:氟塑料绝缘耐高温控制电缆适用于交流额定电压450/750V及以下控制、监控回路以及电器仪表的连接线和自动控制系统的传输线。

国标GB4706.规定的电线负载电流值(部分)1平方铜芯线允许长期负载电流为:6A---8A1.5平方铜芯线允许长期负载电流为:8A---15A2.5平方铜芯线允许长期负载电流为:16A---25A4平方铜芯线允许长期负载电流为:25A---32A6平方铜芯线允许长期负载电流为。
This process specification provides for rated voltage 450/750v, single core 1.5-500mm2 PVC insulated or polyolefin insulated flame-retardant fire resistant soft cable; And 0.6/1kv single core 4~500mm2, 2~5 cores 1.5~240mm2 polychlorinated insulated or polyolefin insulated flame-retardant fire resistant flexible cables process specifications, technical re, and acceptance rules. The main models of this process specification are: rated voltage 450/750v: za-rv; WDZA - RY, etc. Rated voltage 0.6/1kv: za-rvv, za-rvv22, wdza-ryy, wdza-ryy23, wdna-ryy, wdna-ryy23. 2? Usage characteristics, classification and nomenclature of cables 2.1? Service characteristics 2.1.1 cable rated operating voltage: 450/750v, 600/1000v. 2.1.3 temperature under installation should not below 0 ℃. 2.1.4 small bending radius of cables: unarmored cables: the flame retardant type is 6 times the outer diameter of cables, and the fire resistant type is 12 times the outer diameter of cables; The armored cable is 20 times the outer diameter of the cable. 2.2? The cable type consists of 5 parts: serial code, insulation, sheath material code, outer sheath and performance code.
但必须注意,切断了电源,主电路直流部份滤波电容放电也需要时间,需带充电指示灯熄灭后,用万用表等测量,确认直流电压已降到安全电压(DC25V一下)后,在进行检查。
定期检查项目有:输入、输出端子和铜排是否过热、变色、变形?控制回路端子螺钉是否松动,用螺钉旋具拧紧?输入R、S、T与输入U、V、W端子座是否有损伤?R、S、T和U、V、W与铜排链接是否牢固?主回路和控制回路端子绝缘是否满足要求?电力电缆和控制电缆有无损伤和老化变色?污损的地方,用抹布沾上中性化学剂擦拭;用吸尘器吸去电路板、散热器、风道上的粉尘,保持变频器散热性能良好。
1kV-35kV阻燃交联聚乙烯绝缘电力电缆产品标准:本产品按GB1270《额定电压35kV及以下铜芯、铝芯塑料绝缘电力电缆》标准生产,还可根据用户需要按国际电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。

MHY32煤矿用聚乙烯绝缘钢丝铠装聚氯乙烯护套通信电缆用于平巷、竖井或斜井作主信号传输。
KVVP型、ZR-KVVP型450/750V铜芯聚氯乙烯绝缘聚氯乙烯护套编织屏蔽控制电缆 。
KVVP2型、ZR-KVVP2型450/750V铜芯聚氯乙烯绝缘聚氯乙烯护套铜带屏蔽控制电缆 。
聚乙稀绝缘综合护套钢带铠装聚氯乙烯护套铁路信号电缆PTYA23PTYA22PTY23PTY22PTYAH23PZYA23PZYA22PZY23PZY220.8mm(1/1.0MM)4-61芯适用于交流额定电压500V或直流电压1000V及以下传输音频信号及固定敷设的铁路信号和集团自动化装配的控制线路。
2、电缆的使用特性及运行敷设条件额定电压0.6/1KV聚氯乙烯绝缘动力电缆①电缆导体的长期允许工作温度:≤70℃②短路时(最长持续时间不超过5S)电缆的最高工作温度:160℃③电缆敷设后经受直流电压3.5KV/15min不击穿。