Power cable installation considerations, characteristics and operation condition 1, power cable installation considerations for cable laying parallel with heat pipe installation to keep a distance of 2 m, when crossing, should keep 0.5 m. The cable shall be installed at a distance of 0.5m in parallel or across other pipelines. When the cable is directly buried and installed, the direct buried depth of 1-35kv cable is less than 0.7m. When 10KV and below cables are installed in parallel, the net distance between them shall not be less than 0.1m and 10-35kv shall not be less than 0.25m. The distance of cross installation is not less than 0.5m. Cable laying temperature lower than 0 ℃, bending radius: multi-core cable or 15 (D + D), a single cable 20 or more (D + D), (D for cable diameter, D) for the conductor diameter.

本产品是阻燃类产品。
二、执行标准 MT818.《煤矿用阻燃通信电缆》及企业标准Q/JG。
三、使用特性 1、电缆长期工作温度:-30~60℃ 2、电缆敷设温度: 不低于0℃ 3、MHYV型弯曲半径不小于电缆直径的10倍。
电子计算机电缆适用于发电、冶金、石化等工矿企业集散系统、电子计算机系统、自动化系统的信号传输及检测仪器、仪表等,做连接线。
使用环境:1.工作温度:一般型不超过70℃,型号后带105的最高不超过105℃。
This process specification provides for rated voltage 450/750v, single core 1.5-500mm2 PVC insulated or polyolefin insulated flame-retardant fire resistant soft cable; And 0.6/1kv single core 4~500mm2, 2~5 cores 1.5~240mm2 polychlorinated insulated or polyolefin insulated flame-retardant fire resistant flexible cables process specifications, technical re, and acceptance rules. The main models of this process specification are: rated voltage 450/750v: za-rv; WDZA - RY, etc. Rated voltage 0.6/1kv: za-rvv, za-rvv22, wdza-ryy, wdza-ryy23, wdna-ryy, wdna-ryy23. 2? Usage characteristics, classification and nomenclature of cables 2.1? Service characteristics 2.1.1 cable rated operating voltage: 450/750v, 600/1000v. 2.1.3 temperature under installation should not below 0 ℃. 2.1.4 small bending radius of cables: unarmored cables: the flame retardant type is 6 times the outer diameter of cables, and the fire resistant type is 12 times the outer diameter of cables; The armored cable is 20 times the outer diameter of the cable. 2.2? The cable type consists of 5 parts: serial code, insulation, sheath material code, outer sheath and performance code.

VV32-PYJV32-PVLV32-PYJLV32-P聚氯乙烯(交联聚乙烯)绝缘金属屏蔽细钢丝铠装聚氯乙烯护套电力电缆。
YJLV42-P聚氯乙烯(交联聚乙烯)绝缘金属屏蔽粗钢丝铠装聚氯乙烯护套电力电缆。
检修工作方案。
工作人员在完成电力设备的检修与维护工作后,应对设备的各项参数信息进行综合分析和评估,并将评估结果纳入电子资料库当中,为了提高检修与维护工作质量,应针对当前的工作方案进行定期审视并予以调整和完善,做好设备的分类管理工作合理安排不同的维护检修计划和技改项目,还应注意新进设备的检修与维护,有针对性地对设备进行管理,保证相关工作的有序进行。
提高设备的消缺管理力度。
在电力设备投入系统应用之前,工作人员一定要对不同设备的应用技术进行全面而系统性的了解和把握,参与设备的生产关键环节、出厂前验收、现场验收和安装过程。
自承式电缆识别和长度标记:电缆外表面有**性识别标记,标记间隔不大于1m,标记内容有:导线直径,线对数量,电缆型号,制造厂厂名代号及制造年份,长度标记以间隔不大于1m标记在表面上HYAT通信电缆用途:主要用于传输音频、150kHZ及以下的模拟信号2048kbit/s及以下的数字信号。
450/750 v polyvinyl chloride insulated control cable, applicable to dc and ac 50 hz, rated voltage 450/750 v power plants, power plants, factories, mines, ports and petrochemical enterprises such as long-distance control loop, as a connecting line between electrical instrumentation and automation instrumentation, phoresy all kinds of electric energy role, make the whole electric, reliable operation.
The outer conductor knitting is usually 60%-80% suitable. The mould design and processing for insulation production are also key. It should ensure that the product reaches the ideal uniform structure and the e interface constant meets the design re.
MHYBV(PUYBV)煤矿用聚乙烯绝缘镀锌钢丝编织铠装阻燃聚氯乙烯护套通信电缆5-501/0.8用于机械冲击较高的平巷、斜巷。
MHYAV(PUYAV)煤矿用聚乙烯绝缘铝/聚乙烯粘结护层阻燃聚氯乙烯护套通信电缆/0.81/1.0用于较潮湿的斜井和平巷作通信线。

阻燃电缆发展电线电缆行业是中国仅次于汽车行业的第二大行业,产品品种满足率和****占有率均超过90%。
在世界范围内,中国电线电缆总产值已超过美国,成为世界上第一大电线电缆生产国。
伴随着中国电线电缆行业高速发展,新增企业数量不断上升,行业整体技术水平得到大幅提高。
4.成缆时把四根线芯排列为红,绿,蓝,白,排流线,排流线要和线芯一起绞合,千万不要纵放,成缆时不要加填充物,缆芯外用铝箔绕包,而后再绕包一层聚酯膜,在外有一层铜丝编织屏蔽(屏蔽铜丝不镀锡)。
5.护套:护前直径是8.2毫米,护后直径12毫米(11.7--12毫米之间),护套为阻燃蓝色护套一、产品用途及特点:本产品适用于矿山、井下环境监控系统中传输通信信号。
从另一方面看,同步方式要求进行信息传输的双方必须用同一个时钟进行协调,正是这个时钟确定了同步串行传输过程中每一个信息位的位置。
这样一来,如果采用同步方式,那么,在传输数据的还必须传输时钟信号。
而在异步方式下,接收方的时钟频率和发送方的时钟频率不必完全一样,而只要比较相近,即不超过一定的允许范围就行了。
在数据传输中,较为广泛采用的是异步通信,异步通信的标准数据格式如所示。
异步通信数据格式从所列格式可以看出,异步通信的特点是一个字符一个字符地传输,并且每个字符的传送总是以起始位开始,以停止位结束,字符之间没有固定的时间间隔要求。
本产品具有较强的抗电磁干扰、抗雷击及均匀电场,改善供电品质的特性。
特别适用具有精密电子装置的场所,如计算机中心、航空航天监控中心、智能大厦等。
本产品按GB9330《塑料绝缘控制电缆》、IEC60227《额定电压450/750V及以下聚氯乙烯绝缘电缆》以及IEC60502《额定电压1-30KV挤包绝缘电力电缆及附件》等标准制造。

KYJV22ZR-KYJV22铜芯交联聚乙烯绝缘聚氯乙烯护套钢带铠装控制电力电缆敷设在室内、电缆沟、管道、直埋等能承受较大机械外力等固定场合。
KYJV32ZR-KYJV32铜芯交联聚乙烯绝缘聚氯乙烯护套细钢丝铠装控制电力电缆敷设在室内、电缆沟、管道、竖井等能承受较大机械拉力等固定场合。
DJVVP2-22 24×2×0.5(.5)铝塑复合膜分对屏蔽铠装。
DJVVP2-2219×2×0.5(.5)铝塑复合膜分对屏蔽铠装(DJVVP2,计算机用屏蔽电缆,计算机屏蔽电缆)。
DJVVP2-228×2×0.5(.5)铝塑复合膜分对屏蔽铠装(DJVVP2,计算机用屏蔽电缆,计算机屏蔽电缆)。
MHYA32(PUYA32)煤矿用聚乙烯绝缘铝/聚乙烯粘结护层镀锌钢丝铠装阻燃聚氯乙烯护套通信电缆/0.81/1.0用于煤矿竖井和斜井作通信线。
2.使用特性1额定电压U0/U为300/500V及以下。